Telephone / WhatsApp:
+86 18924874907

Hybrid Solar Inverter Charger Manufacturer
16-year experience  ○Factory wholesale  ○OEM/ODM

Welcome to the website of Guangdong Xindun Power Technology Co.,Ltd.

中文English

PRODUCTS

Guangdong Xindun Power Technology Co.,Ltd.
Tel./Whatsapp/Wechat: +86 18924874907
E-mail: sales@gdxindun.com

Add: 3/F,Bldg.3,area C,European Industry Park,Chancheng Dist,Foshan,Guangdong,China

Details
Position: Home> Details

Purchasing Hotline+86 18924874907

Share:

Application:

Uninterruptible Power Supply(UPS); Emergency Power Supply(EPS);

Emergency Backup Power;               Emergency Light;

Railway System;                                Aircraft Signal System;

Alarm and Security Systems;            Electronic Instruments and Equipment;

Telecom Communication System;     DC Screen Power Supply;

Navigation Mark Signal System;        Solar Wind Energy System.


XD100-12 Battery (12V100Ah-Long)

  • XD100-12 Battery (12V100Ah-Long)
XD100-12 Battery (12V100Ah-Long)
  • 产品介绍
  • 右边简介
  • 产品介绍(手机)

specification
Nominal Voltage12V
Nominal Capacity   (10HR)100AH
Battery   sizeLength407±3mm (16.0 inches)
Width173±2mm (6.81 inches)
Height208±2mm (8.18 inches)
Total Height (including terminal)233±2mm (9.17 inches)
Weight28 kg (65.0 lbs)
Terminal   typeT11/T10
Housing   materialABS
Rated Capacity104.0 AH/5.20A (20hr   ,1.80V/Cell,25℃/77℉)
100.0   AH/10.0A (10hr,1.80V/Cell,25℃/77℉)
86.0   AH/17.2A (5hr,1.75V/Cell,25℃/77℉)
78.0   AH/26.0A (3hr,1.75V/Cell,25℃/77℉)
61.0   AH/61.0A (1hr,1.60V/Cell,25℃/77℉)
Maximum Discharge   Current1200A (5s)
Battery Internal   Resistance 4.8mΩ
Operating
    Temperature Range
Discharging-15 ~ 50℃ (5 ~ 122℉)
Charging0 ~ 40℃ (32 ~ 104℉)
Storage-15 ~ 40℃ (5~ 104℉)
Rated   Operating Temperature25±3℃ (77±5℉ )
RecycleAt a   temperature of 25 °C and  a   voltage  of  14.4 V to 15.0 V,  the initial charge current is
     less than 30.0 A.  The correction  factor    is -30mV/°C
Floating   Charge At a   temperature of 25℃ and a voltage of 13.5 V to 13.8 V, the initial charging   current
     is not limited. The correction   factor is -20mV/°C
Capacity affected
      by temperature
40℃(104   ℉)103%
25℃( 77 ℉ )100%
0℃( 32 ℉ )86%
Self-dischargeAt a   temperature of 25℃, the battery can store up to 6 months and then need to be   recharged once.  If the battery is   stored
    at a higher temperature, the storage interval will be shortened

Constant current   discharge meter at 25 °C (77 °F)( Amperes)

Voltage
               Time
5 minutes10 minutes15 minutes20 minutes30 minutes45 minutes1 hour2 hours3 hours4 hours5 hours6 hours8 hours10 hours20 hours
1.85V/Cell171.2134.6114.495.776.157.647.130.023.719.415.613.611.09.445.15
1.80V/Cell229.7171.9138.3113.189.867.052.832.825.620.716.814.611.710.05.2
1.75V/Cell259.0188.9151121.793.269.555.334.026.021.217.215.011.910.15.25
1.70V/Cell285.2205.9161.2127.997.072.357.035.326.821.717.715.312.110.25.35
1.65V/Cell314.5222.2171.4135.9102.374.158.936.327.922.518.115.612.310.45.42
1.60V/Cell346.9241.3183.4144.8108.077.261.037.628.723.218.716.012.410.55.45


Previous
Next

Recommend

Purchasing

* Tel/Whatsapp:
* E-mail:
* Purchase Intention:
Submit