| Specification |
| Model PD-T | 35112 | 50112 | 10224 |
| Rated Power | 350W | 500W | 1000W |
| Peak Power(20ms) | 1050W | 1500W | 3000W |
| Start Motor | 0.3HP | 0.5HP | 1HP |
| Battery Voltage | 12VDC | 12VDC | 24VDC |
| Size(L*W*Hmm) | 310*240*115 |
| Packing Size(L*W*Hmm) | 370*320*200 |
| N.W.(kg) | 5 | 6 | 8 |
| G.W.(kg)(Carton Packing) | 6 | 7 | 9 |
| Installation Method | Desktop |
| Parameter |
| Input | DC Input Voltage Range | 10.5VDC-15VDC(Single battery voltage) |
| AC Input Voltage Range | 73~138VAC/145~275VAC |
| AC Input Frequency Range | 45HZ-65HZ |
| Max AC charging current | 15A MAX(Depending on the model) |
| AC charging voltage | LEAD battery:Charge Voltage :14V; Float Voltage:13.8V(Single battery voltage) |
| AC charging method | Three-stage (constant current, constant voltage, floating charge) |
| Output | Efficiency(Battery Mode) | ≥85% |
| Output Voltage(Battery Mode) | 110VAC±2% / 220VAC±2% |
| Output Frequency(Battery Mode) | 50/60HZ±1% |
| Output Wave(Battery Mode) | Pure Sine Wave |
| Efficiency(AC Mode) | >99% |
| Output Voltage(AC Mode) | 110VAC±10% / 220VAC±10% |
| Output Frequency(AC Mode) | Tracking Automatically |
Output waveform distortion (Battery Mode) | ≤3%(Linear load) |
| No load loss(Battery Mode) | ≤0.8% rated power |
| No load loss(AC Mode) | ≤2% rated power( charger does not work in AC mode) |
| No load loss(Energy saving Mode) | ≤10W |
| Battery Type | Customize battery | Charge and discharge parameters of different types of batteries (such as lithium batteries, etc.) can be customized according to user requirements |
| Protection | Battery undervoltage alarm | 11V(Single battery voltage) |
| Battery undervoltage protection | 10.5V(Single battery voltage) |
| Battery overvoltage alarm | 15V(Single battery voltage) |
| Battery overvoltage protection | 17V(Single battery voltage) |
| Battery overvoltage recovery voltage | 14.5V(Single battery voltage) |
| Overload power protection | Automatic protection (battery mode), circuit breaker or insurance (AC mode) |
| Inverter output short circuit protection | Automatic protection (battery mode), circuit breaker or insurance (AC mode) |
| Temperature protection | >90°C(Shut down output) |
| Alarm | A | Normal working condition, buzzer has no alarm sound |
| B | Buzzer sounds 4 times per second when battery failure, voltage abnormality, overload protection |
| C | When the machine is turned on for the first time, the buzzer will prompt 5 when the machine is normal |
| Inside Solar controller | Charging Mode | PWM |
| Charging current | 10A,20A,30A |
| PV Input Voltage Range | 12V System:15V-44V;24V System:30V-44V |
| Max PV Input Voltage(At 25℃) | 12V/24V System:50V |
| PV Array Maximum Power | 12V System:140W,280W,420W,560W,700W,840W; 24V System:280W,560W,840W,1120W,1400W,1680W |
| Standby loss | ≤3W |
| Maximum conversion efficiency | >95% |
| Working Mode | Battery First/AC First/Saving Energy Mode |
| Transfer Time | ≤4ms |
| Display | LCD |
| Thermal method | Cooling fan in intelligent control |
| Communication | RS232(Optional) |
| Environment | Operating temperature | -10℃~40℃ |
| Storage temperature | -15℃~60℃ |
| Noise | ≤55dB |
| Elevation | 2000m(More than derating) |
| Humidity | 0%~95% ,No condensation |
| Warranty | 3 years |
| Note: All specifications are subject to change without prior notice |