Specification |
Model SJW | 50112/24 | 70112/24 | 10212/24 |
Rated Power | 500W | 700W | 1000W |
Peak Power(20ms) | 1500W | 2100W | 3000W |
Start Motor | 0.5HP | 0.5HP | 1HP |
Battery Voltage | 12/24VDC |
Size(L*W*Hmm) | 408*296*130 |
Packing Size(L*W*Hmm) | 495*365*220 |
N.W.(kg) | 8.5 | 9.5 | 10.5 |
G.W.(kg)(Carton Packing) | 10 | 11 | 12 |
Installation Method | Wall-Mounted |
Parameter |
Input | DC Input Voltage Range | 10.5-15VDC(Single battery voltage) |
AC Input Voltage Range | 73VAC~138VAC / 76VAC~144VAC / 93VAC~150VAC / 145VAC~275VAC / 152VAC~288VAC / 158VAC~300VAC |
AC Input Frequency Range | 45Hz~65Hz |
Max AC charging current | 15A MAX(Depending on the model) |
AC charging method | Three-stage (constant current, constant voltage, floating charge) |
Output | Efficiency(Battery Mode) | ≥85% |
Output Voltage(Battery Mode) | 110VAC±2% / 115VAC±2% / 120VAC±2% / 220VAC±2% / 230VAC±2% / 240VAC±2% |
Output Frequency(Battery Mode) | 50/60Hz±1% |
Output Wave(Battery Mode) | Pure Sine Wave |
Efficiency(AC Mode) | >99% |
Output Voltage(AC Mode) | 110VAC±10% / 115VAC±10% / 120VAC±10% / 220VAC±10% / 230VAC±10% / 240VAC±10% |
Output Frequency(AC Mode) | Tracking Automatically |
Output waveform distortion (Battery Mode) | ≤3%(Linear load) |
No load loss(Battery Mode) | ≤0.8% rated power |
No load loss(AC Mode) | ≤2% rated power( charger does not work in AC mode) |
No load loss(Energy saving Mode) | ≤10W |
Battery Type (selectable) | LEAD | Charge Voltage: 14V; Float Voltage: 13.8V(Single battery voltage) |
OP-LE | Charge Voltage: 14.2V; Float Voltage: 13.8V(Single battery voltage) |
LITHIUM | Charge Voltage :13V(Single battery voltage) |
Customize battery | Charge and discharge parameters of different types of batteries can be customized according to user requirements |
Protection | Battery undervoltage alarm | 11V(Single battery voltage), LITHIUM 9.5V(Single battery voltage) |
Battery undervoltage protection | 10.5V(Single battery voltage), LITHIUM 9V(Single battery voltage) |
Battery overvoltage alarm | 15V(Single battery voltage), LITHIUM 14V(Single battery voltage) |
Battery overvoltage protection | 17V(Single battery voltage), LITHIUM 15V(Single battery voltage) |
Battery overvoltage recovery voltage | 14.5V(Single battery voltage), LITHIUM 13.5V(Single battery voltage) |
Overload power protection | Automatic protection (battery mode), circuit breaker or insurance (AC mode) |
Output short circuit protection | Automatic protection (battery mode), circuit breaker or insurance (AC mode) |
Temperature protection | >90°C(Shut down output) |
Alarm | A | Normal working condition, buzzer has no alarm sound |
B | Buzzer sounds 4 times per second when battery failure, voltage abnormality, overload protection |
C | When the machine is turned on for the first time, the buzzer will prompt 5 when the machine is normal |
Inside Solar controller
| Charging Mode | PWM |
Charging current | 10A,20A,30A |
PV Input Voltage Range | 12V System:15V-44V;24V System:30V-44V |
Max PV Input Voltage(At 25℃) | 12V/24V System:50V |
PV Array Maximum Power | 12V System:140W,280W,420W,560W,700W,840W;24V System:280W,560W,840W,1120W,1400W,1680W |
Standby loss | ≤3W |
Maximum conversion efficiency | >95% |
Working Mode | Battery First/AC First/Saving Energy Mode |
Transfer Time | ≤4ms |
Display | LCD |
Thermal method | Cooling fan in intelligent control |
Communication | RS232/RS485(Optional) |
Environment | Operating temperature | -10℃~40℃ |
Storage temperature | -15℃~60℃ |
Noise | ≤55dB |
Elevation | 2000m(More than derating) |
Humidity | 0%~95% ,No condensation |
Warranty | 3 years |